Recessed fully integrated, multiple source LED lighting system for individual patient care and rest within a ward. DALI protocol to achieve all lighting performance requirements in LG2 & BSEN12464-1:2011, including 1000 lux and Ra90 for examination/treatment. Linear ‘U’ shaped LED luminaire delivers a virtually continuous line of light. LED downlights angled towards task to maximise performance – as Whitecroft Lighting CARELINE
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 13 W | 672 lm | 52 lm/W | 4000 K | 90 |
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 9 W | 600 lm | 67 lm/W | 4000 K | 90 |
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 1 W | 3860 lm | 3860 lm/W | 4000 K | 90 |
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 56.25 W | 3860 lm | 69 lm/W | 4000 K | 90 |
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 1 W | 2574 lm | 2574 lm/W | 4000 K | 90 |
| Lamp type | Nominal lamp power | Total flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| LED | 9.4 W | 600 lm | 64 lm/W | 4000 K | 90 |
Mounting mode
Ceiling recessed
Shape and measurements
Length: 1785 mm
Width: 1185 mm
Height: 151 mm
Adjustability
Fixed
Electric
System power: 89.65 W
Protection
IP: 44
Photometric data
ZIP file