Product data sheet

nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting

nD867F 12L60/3/4 H (86700 0302)

Schuch

Product image 1: nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting
Product image 1: nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting

Product image 1: nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting 

 

IP
66

IK
10

Explosion-protected LED emergency light fitting, ExeLed 2 N, EX-Zone 2/22, 41 W, 6020 lm, 147 lm/W, Self-contained battery, Self test, Emergency operating time 3 h, 750 lm, Class I, IP66, wide beam, 5000 K, CRI≥ 80, Ta -30 °C/+55 °C, L80B50>100000 h (@ Ta max), L80B50>100000 h (@ Ta 25°C), L90B50>75000 h (@ Ta 25°C), Diffuser PC satined, Closure Stainless steel (1.4571), Housing Glass fibre reinforced polyester, Colour grey. Explosion-protected LED emergency light fitting ExeLED 2 N for zone 2/22 and high temperatures. Glass fibre reinforced polyester housing with separate battery box at one small side of the housing, frosted cover made of polycarbonate with silicone gasket and stainless steel clips, two of them as safety clip. Steel reflector, varnished, carrying the LED modules and all electrical components, clipped into the cover, removable as a unit. ECG with automatic monitoring according to EN 62034 and optical indication of the test results. Battery box with NiCd battery and electronic charger, deep discharge protection according to EN 61347-2-7, short circuit protected battery and reverse battery protection. Recharging time: 24h according to EN 60598-2-22. External mounting system for variable mounting (accessory). Resource-saving and environmentally friendly thanks to interchangeability of components (no disposable light fitting). Length 1375,00 mm, Width/Diameter 221,00 mm, Height 114,00 mm, Net weight 7,30 kg. 

Lamp type Nominal lamp power Total flux Luminous efficacy CCT CRI
LED 41 W 6020 lm 147 lm/W 5000 K 80
nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting

nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting 

Light output 1 (integrated) 

LED 

Lamp type Nominal lamp power Total flux Luminous efficacy CCT CRI
LED 41 W 6020 lm 147 lm/W 5000 K 80
nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting

nD867 ExeLed 2 N Explosion-protected LED emergency light\n fitting 

Light output 2 (integrated, emergency) 

LED 

Mounting mode 

Ceiling mounted, Pendant, Contact rail, Wall mounted

Shape and measurements 

Length: 1375 mm

Width: 221 mm

Height: 114 mm

Adjustability 

Fixed

Electric 

System power: 82 W

Appliance Class: I

Information regarding emergency functions 

Supplementary emergency lighting

Emergency sign: N/A

Protection 

IP: 66

IK: 10

Designation labels: CE

Explosion zone suitability: 2

Photometric data

ZIP file