Emergency luminaire For fluorescent lamps GRP Explosion-protected Type: 6409/522-9607-1611-7 Enclosure material: Polyester resin Translucent cover material: Polycarbonate Version: Standard Number of lamps: 2 Lamp wattage: 18 W Dimensions (L x W x H): 857 x 183,5 x 125 mm AC rated operational voltage: 220,00 - 240,00 V Application range (zones): 2 , 21, 22 Gas explosion protection: II 3 G Ex nA d mb IIC T4 Gc Dust explosion protection: II 3 D Ex tc IIIC T80 °C Dc II 2 D Ex tb IIIC T80 °C Db Min. ambient temperature: -20 °C Max. ambient temperature: +50 °C Through wiring: With 6 conductors 2.5 mm2 Installed terminal strip: PE + N + L1 + L2 + L3 + L´ Max. solid connect. terminals: 4,00 mm2 Max. fine. strand. conn. term.: 4,00 mm2 Battery capacity: 7 Ah Battery version: NiCd battery, gas-tight Emergency light operation: Continuous light Or stand-by light Operating time: 1.5 / 3h em. lighting op. Battery operating voltage: 6 V Self-test function: With (standard) Drilled holes: 3 x M25 Accessories: Provided Screw connections: 2 x M25 Ø 7 – 17 mm Cable entry material: Polyamide, black Stopping plug: 2 x M25 x 1.5 Stopping plug material: Polyamide, black For further information, see: r-stahl.com WebCode 6409A
| Available equipment | Nominal lamp power | Lamp flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| 1 x Fluorescent lamp tubular T5 | 18 W | 1350 lm | 75 lm/W | 3000 K | 85 |
| 1 x Fluorescent lamp tubular T5 | 18 W | 1350 lm | 75 lm/W | 4000 K | 85 |
| Available equipment | Nominal lamp power | Lamp flux | Luminous efficacy | CCT | CRI |
|---|---|---|---|---|---|
| 2 x Fluorescent lamp tubular T5 | 18 W | 1350 lm | 71 lm/W | 4000 K | 85 |
| 2 x Fluorescent lamp tubular T5 | 18 W | 1350 lm | 71 lm/W | 3000 K | 85 |
Mounting mode
Ceiling mounted, Pendant
Shape and measurements
Length: 870 mm
Width: 184 mm
Height: 128 mm
Adjustability
Fixed
Electric
System power: 56 W
Appliance Class: I
Information regarding emergency functions
Supplementary emergency lighting
Emergency power supply: Single battery 1 h
Emergency sign: N/A
Protection
IP: 66
IK: 10
Designation labels: CE
Photometric data
ZIP file